Please note this question was answered in 2022. The coding advice may or may not be outdated.
Fistula remote access 36901-52 and 36012
Date: Aug 31, 2022
Question:
Could you please clarify if we can code 36901-52 and 36012? It seems like he moved the catheter back to stent the subclavian after he had accessed the fistula.
"Under sonographic guidance, right common femoral vein was accessed with a 21 gauge micropuncture needle. A 7 French sheath was inserted. Right cephalic AV fistula was catheterized with 5 French Kumple catheter and 0.35 guidewire. Right cephalic fistulogram and central venogram were performed. Right subclavian/innominate venous stenosis was angioplastied with a 12 x 60 mm balloon and stented with a 14 x 60 mm Cook Zilver Vena stent. The stent was dilated with a 12 mm balloon."
Need to ask Dr.Z?
Don't see the answer you're looking for in the knowledge base? No problem. You can ask Dr. Z directly!Ask Dr. Z a question now!