Please note this question was answered in 2020. The coding advice may or may not be outdated.
Angiovac Tricuspid Valve Debulking with ICE
Date: Oct 12, 2020
Question:
Patient presents for Angiovac tricuspid valve vegetation debulking via IJ approach. ICE is used prior to Angiovac extraction to confirm location of vegetation. VV ECMO (percutaneous) is also performed, with US guided vascular access used for cannula insertion. My coding compliance department has rejected my request for set up of 93799 for stand-alone ICE use without an applicable base, and instructed me to use 36013 in past request. So my plan is to code 33999, 76937 x 2, 33946, 33952, and 36013-XS. Do you agree with this coding plan?
Need to ask Dr.Z?
Don't see the answer you're looking for in the knowledge base? No problem. You can ask Dr. Z directly!Ask Dr. Z a question now!