Please note this question was answered in 2020. The coding advice may or may not be outdated.
Catheter Ablation of Atrial Flutter
Date: Jul 20, 2020
Question:
Which code is supported in this documentation? 93656 or 93653? "DuoDeca catheter inserted via right femoral, then placed into coronary sinus for electrogram. The other 8 French sheath was upgraded to a RAMP sheath, and ablation catheter was placed via sheath. Biosense 4-mm tip contact force ablation catheter. Entrainment revealed this was right atrial flutter. Ablation then performed along the cava tricuspid isthmus in the 12 and 6 o'clock positions. Each site ablated between 10-30 seconds with attenuation of electrogram with splits. Atrial flutter was terminated in the IVC and the isthmus."
Need to ask Dr.Z?
Don't see the answer you're looking for in the knowledge base? No problem. You can ask Dr. Z directly!Ask Dr. Z a question now!